Page 63 - SIM Guide to annual assessment_v2.0_Dec 2021
P. 63

Conveyor / Gantry





         Preliminary considerations.
         LOAD LIMITS, CONSTRUCTION ERRORS AND MODIFICATIONS



        VERIFY:
          ▪    Load capacity and operation limits? Do you know it? Is your structure
               designed to support the existing load?
          ▪    Errors in construction? (i.e. span length, size of structural elements type of

               foundations and supports)
          ▪    Material used as per design? (thickness, type of material. fixation,flexible
               connections, concrete, etc).

          ▪    Additions, modifications and changes were controlled and documented?

           IMPORTANT:  Do not allow overloads caused by dust or other materials accumulated on
           your structures.
           Critical Controls must be in place:
                    ○    Documented Structural changes/modifications

                    ○    Safe Operation Limits are known and respected
                    ○    Routine Housekeeping and Inspection
                    ○    Structure is protected (impact by mobile equipment, abrasion and corrosion)



         GENERAL STRUCTURE



         ASSESS


           ●    Corrosion, cracks, delamination, flaked metal, spalling concrete, holes
           ●    Missing elements or sections of the structure


















          NOTES:
















                                                                                                               63
   58   59   60   61   62   63   64   65   66   67   68