Page 39 - Condition Monitor User Manual
P. 39

Adding Sensors






























                                              Figure 5-3 EV Sensor Editor Page 1
                          To add EV sensors:

                          •  Press the ‘Add…’ button.
                          •  Select the type of sensor to add.  The 4 standard Iris Power LP EV sensor types can
                              be  pre-selected  or  select  ‘Custom’.    If  adding  custom  sensors,  some  sensor
                              parameters are required; the high and low cut-off frequencies, the sensor sensitivity
                              and the number of axes the sensor can monitor.
                          •  Select the number sensors to add.

                          •  Press ‘OK’.  This will return you to the main sensor screen and the sensors will be
                              added to the list.

                          •  Once the sensors are added, enter the serial number of each sensor into the table;
                              this will not affect data collection, but could be important for tracking purposes.  If
                              any  sensors  have  the  same  serial  number,  those  sensors  will  have  a  warning
                              indicating so.

















                                                 Figure 5-4 Add EV Sensors





                                                            33