Page 13 - january
P. 13
PRODUCTION AUTOMATION
ports of the programmable logic controller (PLC); 2) in the text of the part program (in the
CNC system), at the desired operation, these M-functions are called before the operation where
adaptation is required. In this case, the control of the cutting parameters is transferred to the
USO, which generates the control signal. The control signal can be represented both in analog
form, with the amplitude proportional, for example, to the feed value, and in digital form. It
depends on the characteristics of the PLC and on whether it has free inputs.
Table 2. Technical characteristics of sensors.
parameter signification
Voltage sensor
Vpn Rated input voltage, eff. meaning 350 В
Vp Conversion range 0…±500 В
Vs Analog voltage output 5 В
KN Conversion factor 1:1000
VC Supply voltage (± 5%) +15 В
f Frequency Response (- 1dB) at 50% of Vpn 0…300 khz
кГц
Current sensor
IPN Rated input current, eff. meaning 150 А
Ip Conversion range 0…±200 А
Vs Analog voltage output 0,5 В
KN Conversion factor 1:1000
VC Supply voltage (± 5%) +15 В
f Frequency Response (- 1dB) 0…200 khz
Vibration sensor
Ap Conversion range 50 g
Vs Analog voltage output ±5 В
KN Conversion factor 0,1 В/g
VC Supply voltage (± 5%) +15 В
f Frequency Response (- 1dB) 0,001…10 khz
Stanochniy park 13