• Granules of uniform size.
    • Proper hopper design.
    • Addition of glidant.

9. Poor Hardness:
Causes:

    • Low binder concentration.
    • Insufficient compression force.
    • Granule too coarse or too dry.

         Remedy:
    • Optimize binder and compression.

10. Prolonged Disintegration:
Causes:

    • Excess binder or lubricant.
    • Overdrying of granules.

         Remedy:
    • Adjust binder/lubricant levels.

11. Poor Dissolution:
Causes:

    • Same as prolonged disintegration.
    • Hydrophobic lubricant film.

         Remedy:
    • Reduce lubricant mixing time.
    • Use hydrophilic additives.

Environmental Controls in Tablet Production:
    • Temperature: 20–25°C.
    • Relative humidity: 45–55%.
    • Air filtration to avoid contamination.
    • Dust extraction system required.