Page 97 - TCDB combined Book
P. 97

Chapter   2      SALES        73





               Presentation Booklet:        Sample Proposal              Outline Specifications







                     l�L                                                        Outline Specifications
                                                                                           for
                                 CONSTRUCTION                                   ACME Manufacturing
                      YOUR   CO NPLET E  DESJG  N-8UJLDER






                       800 - DOORS & HARDWARE




                                 Door Frames

                                 Provide standard 2” deep pressed steel frames, with throat size to wrap wall thickness,
                                 reinforced and blanked to suit the hardware to be installed. Door frames at interior to be 18
                                 gauge, exterior 16 gauge. Fire rated openings to have appropriate ULC labeled frames.




                                 Doors

                                     All exterior personnel doors set in pressed steel frames to be hollow metal, 18 gauge, 1-
                                     3/4” thick, insulated, with cut outs and reinforcing to suit hardware to be installed.

                                     All interior doors, other than doors from office to plant and at stairwells, to be solid core
                                     wood with hardboard paint grade finish. Fire rated doors at stairwells and from plant to
                                     office to be hollow metal, 1-1/34” thick and have the appropriate ULC label affixed

                                     Commercial aluminum entrances at both main office entry points (2) to be standard
                                     color, prepainted single units with sidelite and transom panel. Glazing to be tempered
                                     clear thermopane. Hardware to consist of push and pull bars with deadbolt lock and
                                     closure.

                                     Overhead doors at plant, two (2) 12.0 ft. wide x 14.0 ft. high, set in a structurally framed
                                     opening, prime painted sectional metal, insulated, with 3” hardware and chain hoist
                                     manual operation.