68                          The Complete DESIGN-BUILDER






               Presentation Booklet:        Sample Proposal              Outline Specifications




                                                                          Outline Specifications
                         l�L                                                         for
                                      CONSTRUCTION                        ACME Manufacturing
                          YOUR   CO HPLET E  DESIG N-8UILDER







                       400 - MASONRY





                          Bearing Walls (inside plant area)

                          Provide standard 8” thick exposed masonry units (12 courses high = 8.0 ft.) to enclose the plant area
                          offices, separate rooms and for support of the wood framed mezzanine floor above. Masonry   work to
                          have vertical and horizontal reinforcing steel with concrete fill and tooled joints where exposed.
                          Masonry work to be designed by a registered professional engineer.





                          Exterior Walls

                                 Plant
                                 Provide 4” thick split face gray standard masonry units (15 courses=10.0 ft. high) backed with
                                 6” standard steel studs spaced @ 16” c/c with standard ½” thick sheathing and 1” air space to
                                 exposed portion of front wall and one complete side wall (shipping/receiving side).

                                 Office
                                 Provide standard 4” face brick to the entire lower portion (10.0 ft.) of the exposed office
                                 building walls, complete with 6” standard steel stud backup, standard ½” sheathing and 1” air
                                 space. (Refer to brick purchase allowance)