Page 91 - TCDB combined Book
P. 91

Chapter   2      SALES        67






               Presentation Booklet:        Sample Proposal              Outline Specifications





                                                                            Outline Specifications
                         l�L                                                          for
                                      CONSTRUCTION                          ACME Manufacturing
                          YOUR   CO NPLET E  DESJG  N-8UJLDER






                       300 - CONCRETE WORK




                          Foundations

                              Provide poured in place reinforced concrete (4000 psi) footings, walls and piers designed to
                              support the intended loads, reactions and forces from the building structure. Foundation design is
                              based on the soils report number 040294 prepared by XYZ Geotechnical  provided for this
                              purpose, with a soil bearing allowance of 3000 psf.




                          Concrete Slabs

                              Slabs on grade to be poured in place (4000 psi) concrete, reinforced with one layer of 6x6-6/6
                              welded wire mesh, complete with perimeter expansion joint material, sawcuts and mechanical
                              steel trowel finish. Slab to be thickened as required under masonry load bearing walls.

                              Office - 4” thick with plain finish.
                              Plant  - 6” thick with 40-pound non-metallic hardener and one coat of clear sealer.

                              Slab on deck to be poured in place (4000 psi) concrete with one layer of 6x6-8/8 welded  wire
                              mesh, complete with perimeter edge angle and mechanical steel trowel finish.

                              Second Floor/stairs, landings - 2-1/2” thick with plain finish.


                          General Notes:

                          �    Reinforcing steel to be intermediate grade ksi
                          �    Expansion joint material to be 1/2” thick premoulded
                          �    All concrete work to be designed by a registered professional engineer.
                          �    Set building column anchor bolts as per layout and within standard tolerances.
   86   87   88   89   90   91   92   93   94   95   96