Page 95 - TCDB combined Book
P. 95
Chapter 2 SALES 71
Presentation Booklet: Sample Proposal Outline Specifications
Outline Specifications
l�L for
CON5TRUCTION ACME Manufacturing
YOUR CO NPL£T £ DESIG N-BUILDER
700 - MOISTURE PROTECTION
Foundation Insulation
Provide 2” thick rigid insulation (R 5.0 per inch) to a depth of 2.0 ft. below finished grade to
inside face of the entire building foundation exterior.
Wall Insulation
Office building exterior walls to be insulated with 6” of fiberglass friction-fit batt type
insulation (R-20) complete with 6 mil polyethylene vapor barrier
Plant building exterior walls to be insulated with 6” of fiberglass blanket type insulation
(R-20) complete with an integral reinforced vinyl vapor barrier facing. Lower portion of
exterior walls with architectural block to be insulated with 6” of fiberglass friction-fit batt
type insulation (R-20) complete with 6 mil polyethylene vapor barrier.
Roof Insulation
Office building to be insulated with 4” of rigid roof insulation (R-20).
Plant building to be insulated with 6” of fiberglass blanket type insulation (R-20)
complete with an integral, reinforced vinyl vapor barrier facing.
Sound Insulation
Provide 4” and/or 6” thick friction-fit batt-type sound attenuation insulation to all partition
stud walls of private offices, washrooms and demising wall between office and plant.