Page 96 - TCDB combined Book
P. 96

72                          The Complete DESIGN-BUILDER





               Presentation Booklet:        Sample Proposal              Outline Specifications




                                                                               Outline Specifications
                           l�L                                                           for
                                       CON5TRUCTION                            ACME Manufacturing

                            YOUR   CO NPL£T £  DESIG N-BUILDER







                       700 - MOISTURE PROTECTION  (continued)





                          Built-Up Roofing

                                 Office portion to have standard 5 ply tar and gravel built-up roof system over steel deck with
                                 rigid insulation and topping of clear ¾” minus washed gravel complete with galvanized metal
                                 gravel stop.  Roof slopes to drains with built-in pitch from structural roof framing. Fabricate
                                 and install parapet cap flashing supplied by pre-formed wall cladding supplier.




                          Pre-formed Metal Wall Cladding

                                 Office portion at upper second floor level and both entrance canopies to have 24 gauge, 1-
                                 1/2” deep vertical profile, prefinished 10,000 series standard color, metal cladding on 5/8”
                                 deep 18 gauge galvanized horizontal furring at 4.0 ft. centers. Metal wall cladding to be
                                 complete with matching fasteners, sealant and flashing at base and cap, corners, and around
                                 all openings. Provide matching prefinished metal flat stock to roofer for parapet flashing.




                          Caulking

                          Provide the proper commercial quality sealants for interior and exterior applications, color coordinated,
                          to seal all wall and roof openings including doors, windows, mechanical/electrical openings and
                          penetrations, counter tops, frames etc.