AI^N£XURE-II
                                  PROFORMA FOR SUBMISSION OF RAT INSPECTION REPORTS
           S.No. Description
                I
           I. General Particulars of R.A.T.
                Name of the Tank                       Chennaya Gunta Tank
                District                               Chittoor
                Name of Village & Mandal               ^ennaya Gunta (V) in Tirupati Urban Mandal
                Latitude & Longitude                   - -n_  .
                                                       13"38'5S"R7q°28'14"f'^7n/fi|
                Affected Railway Bridge and KM         206 &204 &137/7-8 to 139 KM
                Railway section and between stations
                                                       Renigunta - Kodur
                Distance from Railway bridge to bund (along tfie
                course of Nalla)                       8 KM to 10 KM
           II. Standard Hydraulic details
                Catchment area
                                                       D.95 sg.km.
                Capacity of the tank
                                                       9.13 Mcft
                Lowest bed level
                Full tank level ( FTl '
                                                       100.000 Mts
                Maximum water level I MWl ]
                                                      100.600 Mts
                Danger Level ( ni
                Top of Bund Level I TRl
                                                      101.800 Mts
                Top width of Bund
                                                      3.00 Mts
                Side slopes
                                                      Front: 11/2:1. Rear: 7-1
                  ea of submereiblp at FTL
                                                      0.47 sg.km.
                Area of submergible at MWL
                                                      0.57 sq.Km
            12 Are there any tanks in the catchment of this tar^k.
                                                      No
            13 Arethese tanks also classified as a RAT
                                                      No
            14  Name and details of these tanks
                                                      No
                No. of surplus weirs
                                                      One
                Length of surplus weirs
                                                      30.0 Mts
                Type of surplus weir
                                                      B.C. Weir
            4 [Design discharge
                                                      474.41 cusecs
           IV. Sluice
                                                      One
                                                      170 M from Surplus weir
               Maximum design discharge
               Functional or not
                                                      Functional
           v. A: Inspection Details
               Date of Inspection
                                                     -iL3-.02-2020
               Name and designation ofinspecting officials
                                                     Sri. C. Wilson babu, ADEN, S.C.Railways, Renigunta
                                                     Sri R.M.V.Ramana Murthy, Asst.Engineer, Irrigation
                                                     Section, Tirupati Urban
               If thequality for classification as RAT
                                                     Yes
          B: Tank bund
               Is thetop level ofthebund uniformed and asas
               per the standards                     No
               Is thetopwidth ofthebund asper standards
                                                     Yes
               Arethe slopes as per the standards    Yes
               Any dangerous gullies orscoured the bund
                                                     No
          C; Surplus weir
               Condition                             Good
               Is the length adfequate for design discharge
                                                     Yes
               Is danger level marked
                                                     No
          D:Condition of the sluice
                                                     working
          E:Any past history ofbreach ofthe tank and ifso,
                                                     No
          details



                                                           signA^iS FANI
               Assistant
                                                              i;?w»wriafijiSECTio7>j'
                  5.31.S.C.Railway                              tirupathi urban
                            I Renigunta