Page 115 - QR KLINDEX EXPANDER850AT-RXt
P. 115

SAFETY DEVICES OF THE APPLIANCE

7	 Safety devices of the                                          7.3	 Emergency button
     appliance
                                                                  The emergency stop button is used to stop appliance
7.1	 General information                                          operation in the event of a hazard or malfunction
                                                                  without the operator having to switch the appliance
l	NOTICE                                                          off. It is located on the electric panel, on the control
             Never use the appliance with faulty safe-            panel and on the radio control. All three buttons are
             ty devices or if these safety devices have           independent of each other.
             been tampered with. Before use, always
             check the safety devices as indicated in                                                                                                    ON                        W
             the following chapter. In the event of a                                                                                                     W              RX
             fault, contact the Authorised Repair Cen-
             tre.                                                                                                                                         TX

                                                                                                                                                0

                                                                  SPEED    UP  POWER        RT LT            RESET     EMERGENCY
                                                                         DOWN      ON                                        STOP

                                                                                                                                          LEFT RIGHT              SWING
                                                                                                                                                    UP

                                                                                                                                   SPEED        DOWN                                  MAN AUTO
                                                                                                                                                     STOP

                                                                                                                                          LEFT             RIGHT

                                                                                                                                   PLANETARY                      STOP

Before checking the safety devices, act as follows:                            1 = OFF = 2
–	make sure that the caster wheel is inserted and
                                                                                MODALITÀ  LEVIGATURA
  locked                                                                       TRASPORTO
–	the planetary must be fully raised from the floor: act
                                                                                   OFF                 PLC   GRINDING TRANSPORT
  on the joystick on the control panel and on the radio                        12                     READY
  control to raise/lower the planetary                                                                       POWER OK  MODE
–	the appliance must not be fitted with any tools.
                                                                                                                       OK
                                                              UP
                                                                                                                       LOW
                                                            DOWN
                                                                  7.3.1	 Appliance emergency stop
7.2	 Network tester
                                                                  To stop appliance operation, act in one of the follow-
The appliance is fitted with a network tester which ac-           ing ways.
tivates when the power supply is present in all three
phases and is within operating limits. If the voltage             Button on the radio control and electric panel
values are correct, the white light on the electric panel         –	press the emergency button on the radio control.
(connected to the phase relay) activates. The tester is
set to the default settings.                                        The radio control switches off, the green LED on the
                                                                    electric panel remains on
l	NOTICE                                                          –	for additional safety, press the emergency button
             If the power supply voltages are different             on the electric panel. The emergency button on the
             from the set values, contact the supplier              panel starts to flash
             to intervene correctly on the appliance.             –	to restore appliance operation, first of all restore
                                                                    the emergency button on the panel followed by the
                                                                    button on the radio control, turning it to the right.
                                                                    The emergency button of the electric panel stops
                                                                    flashing. Lastly, reactivate the radio control by act-
                                                                    ing on the reset key
                                                                  –	to reactivate the radio control, release the emergen-
                                                                    cy button turning it to the right. Then press the reset
                                                                    button twice until the blue RX LED activates.

www.klindex.com - Made in Italy                                                                                                                                                                 25
   110   111   112   113   114   115   116   117   118   119   120