Page 15 - Chemical Tire Applicator™ / Wheel Brite Applicator™
P. 15

CHEMICAL TIRE APPLICATOR™
                       WHEEL BRITE APPLICATOR™


                       Installation


                       Tank and Frame Assembly
                              1)  Position  tank and frame assembly on equipment  room wall 54” above floor. This will allow for
                                 placement of most chemical drums.
                              2)  Level unit and fasten to wall (fasteners not supplied by Belanger, Inc.). Make sure structure is
                                 rigid.
                        Air pressure                 Wall mounted air panel
                         adjustment                                                          Pump (right side)


                     Main air supply
                      80-PSI maximum                                 Pump
                                                                                             Pump

                                                “MATERIAL IN”
                        Air regulator            feed from tank
                                                                                       “MATERIAL OUT”
                                                                                        Feed to treadle

                                Hydrominder™          Water inlet valve

                                                                        Main water feed


                         Suction hose,                                             Suction hose
                           Feed from                                               Feed to pump
                        chemical drum,                                             (left side)
                          (replaceable                                             “MATERIAL IN”
                         orifice located
                              here)




















                                                                  Strainer with foot valve
                                                        Float
                                 Lab cock valve














                       1MANUL088             Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        13