Page 96 - PIGNAT catalogue 2020 GB_092020
P. 96

INDUSTRIAL WASTE TREATMENT




                                                    SMT/2000  MOBILE CHEMICAL WASTE TREATMENT


                                                    ➢     Educational approach of the principles of waste disposal, treatment of
                                                          chemical acidic, basic or containing metal ions pollution


                                                    Characterization of the type of pollution and identification of treatment
                                                          Determination of acidic or basic solutions pH
                                                          Neutralization by addition of suitable reagent
                                                          Approach techniques of neutralization of a known metal ion (with optional O2)

                                                    Unit for use in the program QEH of the establishment
                                                          Internal neutralization of chemical waste generated during the practical sessions
                                                          Mobile unit allowing movement of the device on the production site of pollution



                                                           General specifications
                                                                                          Instrumentation
                                                     •  Glass  reactor,  jacketed  for  cooling  by   • Portable temperature probes Pt100Ω.
                                                      circulating cold water, protection of the
                                                                                  • pH probes with electronic transmitter.
                                                      tank by polyester plate.
                                                                                  • Flowmeter.
                                                     •  Variable speed stirring, PTFE.
                                                       •  Dosing pumps
                                                    www.pignat.com
                                                  www.pignat.com                      Dim: 175 x 75 x 190 cm -  150 kg

                                                     •  Glass  settler,  draining  valve  at  the
                                                      bottom, protection by Surlyn coating.
                                                                                        100 - 240 V
                                                                                                        Drainage
                                                                                                 Water

                                                                                                500 L / h
                                                                                       1ϕ - 50/60 Hz
                                                     •  Cold water circuit.
                                  CHEMICAL WASTE TREATMENT              TDC/1000


                      ➢    Treatment of inorganic liquid chemical wastes from analysis laboratories

                                                        Apply various treatment processes
                                                                       Dechromatation
                                                                         Neutralisation
                                                                           Hydrolysis
                                                                          Precipitation

                                                                  Study a batch process
                                                       Operating conditions: pH, redox potential
                                                             Multi-purpose nature of process
                                                              Reaction volume from 1 to 10 L

                   General specifications                  Instrumentation
                                              • Flowmeter.
         •  2 Storage flask, glass, graduated, cylindrical.    • Expansion thermometer.
                                              • pH probes.
         •  Stirring  electrical  motor  drive  with  mechanical   • Portable electronic pH meter.
          speed  controller,  stirring  shaft  and  three-paddle   • RedOx probes.
          helix PTFE lined.                   • Portable electronic RedOxmeter.

         •  Glass reactor, jacketed, total draining valve, pH and
          Red-Ox potential measurement well.

         •  Cold water circuit.


                                                          200 - 240 V   Water   100 mbar
                                                        1ϕ or 3ϕ - 50/60 Hz   1000 L / h

                                                            Dim: 200 x 100 x 250 cm -  150 kg

                                                                          Water treatment
        96
   91   92   93   94   95   96   97   98   99   100   101