Page 95 - PIGNAT catalogue 2020 GB_092020
P. 95

PURIFIED WATER-WASTE TREATMENT




                                                 TED/3000  ELECTRODEIONIZATION


                                                 ➢     Production of highly purified water


                                                 Study of a process for electric regeneration demineralization

                                                 Water polishing step in a reverse osmosis








                                                    General specifications                Instrumentation
                                                                              • Temperature probes.
                                         •  2 tanks.
                                                                              • Flowmeters.
                                                                              • Manometers.
                                         •  Centrifugal pump.                 • Electrode of conductivity.
                                                                              • Level sensors.
                                         •  Filter cartridges.

                                         •  Electrodeionization system.

                                         •  Hardness of the water, measurement kit.
                                                    www.pignat.com
                                                  www.pignat.com

                                         •  CO 2, measurement kit.

                                                                                           200 - 240 V
                                                                                                    Water
                                                                                        1ϕ or 3ϕ - 50/60 Hz   1000 L / h   Drainage
                                                                                         Dim: 270 x 125 x 190 cm -  210 kg


                       WASTE TREATMENT BY  ABSORPTION               CAB/1000


                 ➢     Solution decontamination by a reaction with a gas in continuous operation

                                               Study of the hydrodynamics of the column
                                      A method of gas-liquid absorption at different water flow rates

                                                       Measurement of pressure drops

                                                   Example: study of ozone disinfection





                   General specifications                Instrumentation
                                             • Flowmeter.
        •  2 tanks
                                             • Gas flowmeter .
                                             • Manometer.
        •  Column,  analyzer  with  sheath  pH,  plate  with
          sampling,  ozone  inlet  plate  with  sintered.
          DP measurement.

        •  Dosing pump.

        •  Anti-pulsing pot.

        •  Filter regulator with isolation valve.
                                                                  100 - 240 V     2  bar
                                                                 1ϕ  - 50/60 Hz
        •  Hydraulic guard.
                                                           Dim: 105 x 55 x 215 cm -  100 kg


                            Water treatment                                                                  95