Page 72 - Vessel Sanitation Program 2018 Construction Guidelines
P. 72
VSP 2018 Construction Guidelines
17.5.7 Location
Stations can be installed just outside of the entry. Position the handwashing
stations along the passenger flow to the buffets.
17.5.8 Lighting
Provide a minimum of 110 lux lighting at the handwash stations.
17.6 Bar Counter Tops
17.6.1 Access
Bar counter tops are to be constructed to provide access for workers and to
prevent workers from stooping or crawling to access the bar area from pantries
or service areas.
17.7 Cabinet Interiors
17.7.1 Materials
Install COVED stainless steel inserts or seamless stainless steel cabinet interiors
where items such as, but not limited to, soiled FOOD equipment, dry or wet
garbage, or unpackaged FOOD items are stored (Figure 17).
Laminated materials may be used to construct cabinet interiors where items
such as, but not limited to, dry packaged FOODS, clean equipment, clean
linens, and single-use items are stored (Figure 17).
VSP will evaluate cabinet interior materials during the plan review process.
56