Page 77 - Vessel Sanitation Program 2018 Construction Guidelines
P. 77

VSP 2018 Construction Guidelines



                   19.5  Provision Rooms
                          Provide lighting levels of at least 220 lux (20 foot-candles) in provision rooms as
                          measured at 760 millimeters (30 inches) above the deck while the rooms are empty.
                          During normal operations when FOODS are stored in the rooms, provide lighting
                          levels of at least 110 lux (10 foot-candles), measured at a distance of 760 millimeters
                          (30 inches) above the deck.

                   19.6  Bars and Waiter Stations
                          In bars and over dining room waiters’ stations designed for lowered lighting during
                          normal operations, provide lighting that can be raised to 220 lux (20 foot-candles)
                          during cleaning operations (as measured at 760 millimeters [30 inches] above the
                          deck). Provide a minimum light level of 110 lux (10 foot-candles) at handwash
                          stations at a bar, and ensure this level can be maintained at all times.

                   19.7  Light Bulbs
                          Use shielded, coated, or otherwise shatter-resistant light bulbs in areas with exposed
                          FOOD; clean equipment, utensils, and linens; or unwrapped single-service and single-
                          use articles. This includes lights above waiter stations.

                   19.8  Heat Lamps
                          Use shields that surround and extend beyond bulbs on infrared or other heat lamps  to
                          protect against breakage. Allow only the face of the bulb to be exposed.

                   19.9  Track or Recessed Lights
                          Decorative track or recessed DECKHEAD-mounted lights above bar countertops,
                          buffets, and other similar areas may be mounted on or recessed within the
                          DECKHEAD panels without being shielded. But these fixtures must use specially
                          coated, shatter-resistant bulbs.


               20.0  Cleaning Materials, Filters, and Drinking Fountains

                   20.1  Facilities and Lockers for Cleaning Materials

                       20.1.1   Racks
                                Provide BULKHEAD-mounted racks for brooms and mops or provide
                                sufficient space and hanging brackets within CLEANING LOCKERS. Locate
                                BULKHEAD-mounted racks outside of FOOD STORAGE, PREPARATION,
                                or SERVICE areas. These racks may be located on the soiled side of warewash
                                areas.

                       20.1.2   Stainless Steel
                                Provide stainless steel vented lockers with COVED junctures for storing
                                buckets, detergents, sanitizers, cloths, and other wet items.