Page 75 - Vessel Sanitation Program 2018 Construction Guidelines
P. 75

VSP 2018 Construction Guidelines



                       18.13.2  Water Pressure
                                Pressure required for the fresh water sanitizing rinse unless the machine is
                                designed to use only a pumped sanitizing rinse.


                       18.13.3  Conveyer Speed or Cycle Time
                                Conveyor speed in meters or feet per minute or minimum transit time for belt
                                conveyor machines; minimum transit time for rack conveyor machines; or
                                cycle time for stationary rack machines.

                       18.13.4  Chemical Concentration
                                Chemical concentration (if chemical sanitizers are used).


                   18.14  Manuals and Schematics
                          Provide warewash machine operating manuals and schematics of the internal
                          BACKFLOW PREVENTION DEVICES.


                   18.15  Pot and Utensil Washing
                          Provide pot and utensil washing facilities as listed in section 6.2.2.

                   18.16  Three-Compartment Sinks
                          Correctly size three-compartment warewashing and potwashing sinks for their
                          intended use. Use sinks that are large enough to submerge the largest piece of
                          equipment used in the area that is served. Use sinks that have COVED, continuously
                          welded, integral internal corners.

                       18.16.1  Prevent Excessive Contamination
                                Install one of the following to prevent excessive contamination of rinse water
                                with wash water splash:
                                   •  Gutter and drain: An across-the-counter gutter with a drain that divides
                                       the compartments. The gutter should extend the entire distance from the
                                       front edge of the counter to the backsplash.
                                   •  Splash shield: A splash shield at least 25 millimeters (1 inch) above the
                                       flood level rim of the sink between the compartments. The splash shield
                                       should extend the entire distance from the front edge of the counter to
                                       the backsplash;
                                   •  Overflow drain: An overflow drain in the wash compartment
                                       100 millimeters (4 inches) below the flood level.

                       18.16.2  Hot Water Sanitizing Sinks
                                Equip hot water sanitizing sinks with an easy-to-read TEMPERATURE-
                                MEASURING DEVICE, a utensil/equipment retrieval system (e.g., long-
                                handled stainless steel hook or other retrieval system), and a jacketed or coiled
                                steam supply with a temperature control valve or electric heating system.








                                                             59