GuardII+ Indicators


               8.  GuardII+ Indicators


                          The  GuardII+  indicators  are  the  primary  source  of  status  information  when  a
                       connection to the monitor is not available.
                          Use of the indicators for basic troubleshooting is described in Section 7.  This section
                       describes the complete behavior of the GuardII+ indicators.

               8.1.  Front Panel Indicators

                          The indicators on the front panel are the main source of top-level status information.




























                                          Figure 8-1 GuardII+ Front Panel Indicators
                          During the boot process, the Front Panel indicators behave as follows:
                          •  The Power indicator turns orange when power is first applied

                          •  After approximately 20 seconds, the Power indicator will start to blink green
                          •  After approximately 15 seconds more, the Power indicator turns solid green and
                              the GuardII+ has finished booting up.
                          At this point, the other indicators on the front panel will be in their operational states.

               8.1.1.  Power Indicator


                        Behavior           Meaning
                        Off                No ac power applied, or critical power failure
                        Orange             Hardware configuration in progress
                        Green blink        Firmware loading