TARGET
         PROJECT AREA       ILLUMINANCE      DESIGN INTENT                  CONTROL INTENT     WATTS PER S.F.
                                             Vanities and stalls will be
                            10 FC, 20 FC at                                 Occupancy sensors,
         Restrooms                           illuminated via wallwashing and                       0.80W/sf
                            Vanities                                        local switches
                                             wall mount decorative fixtures.
                                             Pendant or beam side mount     Building networked
                                             direct/indirect linear fixture   lighting system, local
                                             mounted 25’ on center to align with
         Tenant Office      30 FC ambient    structural bays will be used for   override switches,   0.85W/sf
                                                                            daylight zone,
                                             ambient light levels.  Task lighting   Occupancy sensors
                                             will be provided at each       on tasklights
                                             workstation.






























































        14th @ IRVING                                                                                             WSP
        Project No.  B1809809.000