Page 75 - 14th @ Irving Basis of Design (internal)
P. 75
14th @ IRVING
64 12 19 15 LEED CS 2009 Scorecard 6/8/2018 Project Manager: Keith Amann Built Ecology
Certified: 40-49 points; Silver: 50-59 points; Gold: 60-79 points; Platinum: 80 - 110 points email: keith.amann@wsp.com
Y H L N TENANT
CREDIT NAME PTS LEED CREDIT REQUIREMENTS SCOPE ITEM ACTION ITEMS / NOTES STATUS TEAM LEAD
Employ entry mats (10' long in direction of travel) at Discuss plans for entrance lobby and potential for
DBB
1 IEQc5: Indoor Chemical & Pollutant 1 major entrances, exhaust and separate areas of Y entry system to capture contaminants. Lease WSP
chemical use, incorporate MERV-13 filters, provide
Source Control (D)
containment for disposal of liquid hazmats. language required for tenant spaces.
Provide thermal comfort controls or operable
1 IEQc6: Controllability of Systems - 1 windows for 50% of occupants and for shared multi- Y Discuss potential with VRF system WSP
occupant spaces.
Thermal Comfort (D)
1 IEQc7: Thermal Comfort - Design 1 Design HVAC systems to meet ASHRAE 55-2004 Y Standard practice WSP
(temperature and humidity)
(D)
Via computer simulation, prescriptive method,
1 IEQc8.1: Daylight & Views - 1 measurement method or a combination thereof: Y Built Ecology to analyze and share results WSP
Achieve daylighting for 75% of all regularly occupied
Daylight (D)
spaces.
1 IEQc8.2: Daylight & Views - Views 1 Incorporate views to exterior for 90% of occupants Y Built Ecology to document WSP
(both in plan and section view.)
(D)
6 0 0 0 Innovation and Design (ID)
Path 1: Innovation and Design - EP - SSc2:
1 IDc1A: Innovation and Design 1 Development Density & Community Connectivity Exemplary Performance Density WSP
Path 1: Innovation and Design - 1 pt for each
1 IDc1B: Innovation and Design 1 innovation (no more than 5 pts) Exemplary Performance Transportation WSP
Path 2: Exemplary Performance: no more than 3 pts
Path 1: Innovation and Design - 1 pt for each
1 IDc1C: Innovation and Design 1 innovation (no more than 5 pts) Low-mercury lighting, other Ops plans WSP
Path 2: Exemplary Performance: no more than 3 pts
Path 1: Innovation and Design - 1 pt for each
1 IDc1D: Innovation and Design 1 innovation (no more than 5 pts) Cooling tower management plan WSP
Path 2: Exemplary Performance: no more than 3 pts
Path 1: Innovation and Design - 1 pt for each Identify health, smart, or other innovative
1 IDc1E: Innovation and Design 1 innovation (no more than 5 pts) opportunities WSP
Path 2: Exemplary Performance: no more than 3 pts
At least one principal participant of the project team
1 IDc2: LEED™ Accredited 1 is LEED Accredited Professional (AP). Built Ecology to document WSP
Professional ( C )
WSP Built Ecology 4 of 4