By default, flow simulations in MAGNET are run at steady state. To perform unsteady (transient) modeling
               in MAGNET, check the box next to ‘Transient’ in the upper-right part of the Default Parameters and
               Options Menu (see Figure 3-10). Required inputs are the start date and time (hour of the day), the time step,
               and the simulation length. Use the texts boxes next to ‘State Date’ (year, month, day), ‘Hr’ (hours), ‘Time
               Step:’ (days), and ‘Simulation Length’ (days) to define user inputs.
               Check  the  box  next  to  ‘Run  Steady  State  at  t=0’  to  use  the  head  distribution  solved  for  steady  state
               conditions as the initial head distribution of the transient simulation (see Figure 3-10).

               Other options for the initial head distribution are shown in Figure 3-11. The ‘Top’ option will use the Top
               Elevation surface assigned by the user (see Section 3.3.1). The ‘Parent’ option uses the head distribution of
               a  larger  Parent  model  spanning  the  new  (Child)  model  domain  (see  Section  3.6).  Head  values  are
               interpolated from the (coarse-grid) Parent model to the (finer-grid) Child model. The ‘Constant’ option will
               assign the value in the text box as a constant head value across the entire domain.


















                   Figure 3-10: Options for unsteady (transient) modeling in MAGNET. Default values/parameters are shown.


















               Figure 3-11: Options for assigning an initial head distribution across the model domain. Default value/parameters
               are shown.