Page 403 - 2018 Racecar Engineering Drag Racing Parts and Accessories Catalog
P. 403

Two Step Mod ule Se lec tor                        Launch Control Module
                 MSD8739                                            Selector MSD8735
                  When used with the Soft Touch Rev Con trol         Make last second launch RPM adjustments
                 or MSD ignition unit, Two Step Mod ule Selec-      right from the driver’s seat. Three Step Module
                 tor allows the user to switch be tween two dif fer ent RPM limits.   Selector has RPM limits for burn-out and top
                 RPM modules must be purchased separately.          end. Plug-in modules must be purchased separately.
                 Two Step Rev Control                               RPM Activated Switches
                 For Digital 6AL MSD8732                             Used for many functions, from turn-
                  Engineered exclusively for use with the           ing on a bulb or solenoid to starting a
                 Digital 6AL ignition, two-step unit allows chang-  timing computer. Switch has two wires,
                 ing starting line limit RPM right from the driver's   one ground and one to open a circuit.
                 seat. Easy-to-read rotary dials allows setting     Plug in an RPM module and wire the
                 RPM limits in 100 RPM increments. Activation wire   switch to the circuit. Once the engine
                 connects to the transbrake, clutch switch or line lock to activate   reaches the selected RPM, the circuit is active until
                 the low RPM limit. Once the switch is released, the low RPM limit   RPM drops below that point. Window switch includes
                 is deactivated as the car launches.                two RPM circuits, one to start and one to discontinue and is ideal
                                                                    for nitrous applications where the system must be shut down
                 Two Step For Ford                  MSD8734         before RPM limit is reached. Compatible with stock inductive or
                 Modular Motors                                     MSD ignitions. RPM modules not included.
                  Specifically designed for late model                   Part No.      Description
                                                                                      RPM Switch
                 Ford modular powered applications, two-step           MSD8950      RPM Window Switch
                                                                       MSD8956
                 rev limiter helps provide quick, consistent launches.
                 Adjustable from 1,800-9,900 RPM using two built-in   Digital RPM
                 rotary dials. Connects to the OEM coils for quick, easy
                 installation.                                      Window Switch MSD8969
                  Part No.    Description                            Switch turns circuits on and off
                  MSD8731    Ford 5.0L Coyote                       at specific RPM intervals. Accepts
                  MSD8734   Ford 4.6L Modular                       an RPM input signal from a negative coil
                                                                    terminal or a tach output from an ignition control or an
                 Two-Step For GM LS                                 ECU. Switch has 200 to 15,000 RPM capability.
                 MSD8733
                  Two-Step provides quick,                          Digital Shift Light
                 consistent launches to GM LS
                 applications. RPM controller allows                 Compact, universal Shift Light is
                 setting a specific RPM limit for the starting       compatible with distributors, coil
                 line, improving reaction and elapsed times. Easy   packs or coil-on-plug ignitions. Six
                 to connect with direct, plug-in connections.       bright LED's are programmed to illuminate from 100-15,900 RPM
                                                                    in 10 RPM increments. GMR pickup is included.
                 Three Step Mod ule Se lec tor                        Part No.       Description
                                                                      MSD8963
                                                                                 Digital Shift Light, Sync Shift
                 MSD8737                                             MSD89631  Digital Shift Light, Single RPM Point
                  Use with the Soft Touch Rev Con trol or
                 MSD Ignitions. It has all the features of          Shift Light MSD8952
                 the Two Step with an additional RPM limit.          The MSD Shift Light will turn on at what ev er
                 Typically used to limit burn-out, starting         spec i fied RPM is chosen. Plug  the RPM module
                 line and top end RPM. Order RPM mod ules           in the front of the Shift Lite. Uses any RPM
                 separately.
                                                                    module from kits listed below.
                 Adjustable Low RPM Module MSD8677
                  Ideal for automatic transmission equipped drag    RPM Module Kits             MSD8744
                 race cars with two- or three-step rev limiters.     Each RPM Module Kit contains five
                 Module may be adjusted to limit starting line RPM   modules within RPM ranges from 3,000
                 between 1,000 and 3,000 RPM.                       to 10,900. Compatible with all MSD
                                                                    accessories that require modules. Avail-
                 RPM Module Selectors                               able in even and odd increments.
                  Plug this selector into a MSD Soft Touch                                Even Increments   Odd Increments
                 Rev Control, or any other accessory that                 Description       Part No.       Part No.
                 uses a plug-in module, and turn the knob to             3,000-3,900 RPM    MSD8743       MSD87431
                                                                         4,000-4,900 RPM
                                                                                            MSD8744
                                                                                                          MSD87441
                 select from among 12 different RPM limits.              5,000-5,900 RPM    MSD8745       MSD87451
                 Retards timing in increments of 0°-11°.                 6,000-6,900 RPM    MSD8746       MSD87461
                                                                         7,000-7,900 RPM    MSD8747       MSD87471
                   Part No.    Description
                   MSD8670    3000-5200 RPM          MSD8673             8,000-8,900 RPM    MSD8748       MSD87481
                   MSD8671    4600-6800 RPM                              9,000-9,900 RPM    MSD8749       MSD87491
                   MSD8672    6000-8200 RPM
                   MSD8673    7600-9800 RPM
                                                                                                               401
   398   399   400   401   402   403   404   405   406   407   408