Page 142 - Feed Lab
P. 142
Suguna Management System Ver 1.0 / SOP / FQL / P3 - 07 Page 1 of 2
7. Determination of Mineral Oil in Oils
SCOPE
To estimate the Mineral oil adulteration in oil.
APPARATUS
FGraduated pipette -1 ml (picture - 1)
FMeasuring cylinder-25ml (picture - 2)
FRound bottom flask (picture - 3)
Picture - 3 Picture - 4
FWater bath (picture - 4)
FAir/water cooled condenser (picture - 5)
Picture - 5
Picture - 1 Picture - 2 PROCEDURE
FTake 25 ml of 1.5 N Alcoholic KOH Solution in a
R.B.Flask. Add 1 ml of sample of oil. (Picture - 6)
REAGENTS
F1.5N Alcoholic KOH - Dissolve 8g of KOH in 100 ml
FBoil on a water bath using an air or water cooled
of alcohol.
condenser till the Solution becomes clear.
FDistilled water ( Picture -7)
Prepared by : Approved by :
128 Director - Technical