Suguna Management System      Ver 1.0 / SOP / FQL / P3 - 07 Page  1 of 2



























           7. Determination                    of Mineral Oil in Oils



           SCOPE
           To estimate the Mineral oil adulteration in oil.

           APPARATUS
           FGraduated pipette -1 ml (picture - 1)

           FMeasuring cylinder-25ml (picture - 2)

           FRound bottom flask (picture - 3)
                                                                       Picture - 3              Picture - 4
           FWater bath (picture - 4)

           FAir/water cooled condenser (picture - 5)












                                                                       Picture - 5



                  Picture - 1              Picture - 2          PROCEDURE
                                                                FTake 25 ml of 1.5 N Alcoholic KOH Solution in a
                                                                   R.B.Flask. Add 1 ml of sample of oil. (Picture - 6)
           REAGENTS
           F1.5N Alcoholic KOH - Dissolve 8g of KOH in 100 ml
                                                                FBoil on a water bath using an air or water cooled
              of alcohol.
                                                                   condenser  till  the  Solution  becomes  clear.
           FDistilled water                                        ( Picture -7)








          Prepared by :                                                             Approved by :