Page 148 - FreesStyler® Installation and Startup
P. 148

®
            INSTALLATION AND STARTUP


            Chapter 9 Optional “Add-On” Items


            Booster Pump


               Example 1



                                                                           To FressStyler®
                                                              Ball Valve #2
                                                                              Applies
                                                                              additional
                                                                              pressure to the
                                                          Ball Valve #3
                                                                              FressStyler®
                                                                              wash process
                                                                              only.
                        Main Water Feed
                                                              Ball Valve #1


                                                                             To Optional Wheel Cleaner
                                                                                   Pumping Station


               Example 2



                                                                                     To FressStyler®

                                                                                    Applies
                                                                                    additional
                                                                                    pressure to the
                                                                                    FressStyler®
                                                                                    wash and the
                  Main Water Feed                                                   wheel cleaning
                                                                                    process
                                                                Ball Valve #3

                                                                                      To Optional Wheel Cleaner
                                                        Ball Valve #1                       Pumping Station
                                                                      Ball Valve #2

                                                  CAUTION

                     When operating the Booster Pump, make sure Ball Valves #1 and #2 are open
                                                    and #3 is closed.

                   If at some point you need to bypass the Booster pump i.e. for maintenance, make
                    sure that Ball Valves #1 and #2 are closed and #3 is open. This will allow you to
                                               continue to run the wash.







            9-16        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681       1MANUL220