Page 25 - Chameleon® Arch Series
P. 25

CHAMELEON® ARCH SERIES


                       Installation


                       Neon Strip Kit Installation and Electrical Connections
                              6)  In a case where the neon strip extends beyond the existing hole pattern, clip the 2” alunimum
                                 extrusion to the bottom of the neon strip at least 1/4” above the plastic ends as shown below.




                                                                                              1/4”
                                                                                            minimum











                              7)  Mark the location of the aluminum channel. Remove the neon strip, drill the two holes and then
                                 screw the extrusion into place.
                              8)  Once all of the aluminum extrusions  have been properly installed, remove the neon strips from the
                                 channel. DO NOT REMOVE THE NEON STRIPS FROM THE PENDANT. Apply drops of silicone
                                 adhesive to the inside corners of the aluminum extrusions spaced one foot apart. See example
                                 below.
                                                                  Apply
                                                                 silicone
                                                                adhesive
                                                                  here






                              9)  Snap the neon strips back into place.

                              Note:  Above image shows the Oval Pendant
                              10)  Run the electrical wires that are on the ends of the neon strips through the front of the pendant and
                                 into the electrical enclosure assembly. Pull the wires into the electrical enclosure far enough where
                                 the neon strips are butted up all the way on the front of the pendant and then tighten the cord grips.
                                 See image below.













                              11)  Run the field connection wire from the supplied transformer through the grommet that is on the top
                                 of the front cover and then into the top of the electrical box. Refer to the wiring images for proper
                                 electrical hookups.