Page 27 - Chameleon® Arch Series
P. 27
CHAMELEON® ARCH SERIES
Installation
Neon Strip Kit Installation and Electrical Connections
13) Run the field connection wire from the supplied transformer through the grommet that is on the top
of the front cover (pendant) and then through the top of the electrical enclosure as shown below.
Typically this lead is run
through the buildings junction
box and conduit with field
installed cable to accommodate
long distances between the
transformer and the arch.
Be sure to install the transformer away from spraying water of the arches and/or wash
equipment.
14) Pull the wire through the enclosure far enough to make connections to the other wires that are in
the enclosure and tighten the cord grip as shown below.
15) Refer to the wiring images for proper electrical hookups. Be sure to create a “loop” in the wire so
that no water can run into the electrical box as shown below.
Looped wire
1MANUL526 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681 23