Page 110 - Saber® Installation & Startup
P. 110

INSTALLATION & STARTUP

            Chapter 6 Frame and Carriage Assembly



            Installing the Front and Rear Sonar Units
            The Sonar Units are to be mounted on the driver side of the Carriage.


             Sonar Unit (typical)









                                  View from exit side






                   1)  Locate and secure the Sonar Unit mounts to the doors of the Carriage Assembly. The doors have pre-drilled holes.
                                                        Connect the leads
                                                        to the Sonar Units
                Run lead
              wire through
                                                                              Sonar Unit
                post here
                                              Sonar Mount
                           Dotted circles are access holes in the mount to manipulate the cable


                   2)  Run the lead wire through the post of the mount.
                   3)  Connect cable to Sonar while applying a small amount of Dielectric Grease.
                   4)  Re-mount Sonar Unit to Sonar Mount.
                   5)  Adjust Sonar Unit to achieve level condition entrance to exit as shown on the next page.
                      Note:  The Sonar Units seeing a solid floor is critical for proper operation. If the is a
                             floor  drain  in  the  path  of  the  sonar  signal,  mount  the  Sonar  unit  on  the
                             passenger side of the carriage.























             6-48   Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681    1MANUL290