Page 24 - DuraTrans XD® Conveyor
P. 24

DURATRANS XD® CONVEYOR



            Installation

            Installing the Electric Drive Unit Components (Exit Section)
            If your conveyor is an electric drive system, it shipped with the motor/gearbox
            assembly already installed. Install the Electric Drive Float valve Assembly using
            the procedure below.
               1)  Locate the supplied Float valve Assembly and remove the fasteners and washers. You
                   can discard the nut as it is only there to hold the fasteners in place during shipping.
               2)  Rotate the assembly to the orientation show below and secure it into place as shown.
                   Before

















                   After



















            Electrical Prints Information
                   See the supplied electrical prints included with the electrical panel for connections.


















            20      Belanger, Inc®. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681        1MANUL010