Page 20 - Wash Around
P. 20
WASH AROUND
Installation
Utilities General
Water Connections
The following section will explain the installation of the water connections.
The copper tubing atop the head frame assembly can be either fed by a single hose or set up as a dual-
feed system. In a single feed setup, the main water manifold can be turned 180 degrees to accommodate
whichever side of the building your main water supply is located.
It is recommended that a licensed electrician and a professional plumber be contracted to
perform all of the electrical and water installations.
Single Feed
1) Determine the side in which you would like to supply the unit with water. If it is not the side that
already has the “Tee” on the manifold, remove the tee with that has two barbed hose fittings and
place it on the opposite side of the machine.
Feed from Main
Feed to other Manifold Water Manifold
Plug (Single feed setup
requires this fitting to be
Main Water Feed replaced with the
supplied Plug located in
the accessory box)
“Tee” (can be
removed and placed
on other side for
single feed)
2) Once the tee has been placed on the appropriate side, connect a 3/4” water feed to the manifold
inlets.
Dual Feed
1) Connect a 3/4” water feed to the two manifold inlets.
Main Water Feed
Plugs (Dual feed setup
requires both fittings to
be replaced with the
Main Water Feed supplied Plugs located
in the accessory box)
Note: If setup in the “System” configuration (i.e. powered from a CCU), the CCU is supplied
with two water solenoids designated to this function.