Page 56 - TopWinder®
P. 56

®
                               ®
             TopWinder


             Maintenance

             Torque Plate and Electric Motor Replacement

                    Note:  The wiring to each Motor must be removed in order to gain access to the bottom of the
                           Gearbox. There you can inspect and change the flat head bolts used to mount the Torque
                           Plate.

                                                  DANGER


                    DISCONNECT MAIN POWER SUPPLY PRIOR TO SERVICING
                                       OR MAINTAINING EQUIPMENT

                Remove Motor Gearbox Assembly
                1)  Turn off the power and place the disconnects in the OFF position.
                    Note:  To ensure safety we recommend following the Lock-out procedure stated above for the
                           main panel prior to servicing the equipment.
                2)  Remove the plastic Cover from the Cover Base by removing the (2) Phillips head screws.
                    See the image below.
                    Note:  Removing the Cover will allow access to the Motor Gearbox mounted on the Torque
                           Studs.





                                                                          Remove Phillip Head Screws











                3)  Check  the  voltage  at  the  Junction  Box  with  a  multi-meter  to  ensure  all  power  has  been
                    properly removed from the circuit and no power is being supplied to the equipment.
                4)  Remove the Junction Box Cover to gain access to the wiring on the side of the Motor.
                5)  Confirm that the wiring has been tagged for terminal location if not previously identified upon
                    installation.  Remove  the  nuts  to  release  wiring  from  the  Terminal  Block.  See  the  image
                    below.

















             52          Belanger, Inc. ®* 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL755
   51   52   53   54   55   56   57   58   59   60   61