Page 18 - H2AIR® Arch
P. 18
®
H2AIR ARCH
Installation
Install Airis® Assemblies onto Air Cannon™ Dryer Housings
5) The Airis® Assemblies will be mounted to the inlet of the Air Cannon™ Housing with the
Cylinder parallel with the outlet of the housing and the Cylinder Bumper facing down, refer to the
image below.
Note: A clockwise (CW) Airis® is to be attached to a CW Air Cannon™ Blower Housing and a
counter-clockwise (CCW) Airis® is to be attached to a CCW Air Cannon™ Blower Housing.
Air Cannon™
Housing Inlet
Air Cannon™
Blower Housing
Airis®
Cylinder for Airis®
Cylinder Bumper
DryLite™ Air Cannon™ with
Airis® CW Assembly Shown
Air Cannon™ Outlet
6) Hold the Airis® over the top of the Inlet Cone and select the four holes that will be used to
mount the Airis® assembly.
Four (4) Holes to be used to
mount the Airis® Assembly
Air Cannon™
Blower Housing
Airis® Assembly
Inlet Cone
14 Belanger, Inc.® *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL958