                Install Airis® Assemblies onto Air Cannon™ Dryer Housings
                    10) Remove the 3/8”-16 Nyloc nuts, flat washers and bolts that are located on the interior flange and
                        in-line with the four Nut Retainers (1RETNR650) that were just removed, refer to the images
                        below.












                                                                         Remove  the  four(4)  sets
                                                                         of fasteners circled these
                                                                         are  in-line  with  the  Nut
                                                                         Retainers just removed.





                                         Images made
                                      transparent for clarity.





                    11) Locate the Airis® accessory box and retrieve the 3/8” lock washers. Using the 3/8”-16 x 1”
                        fasteners that you just removed install a lock washer and then one of the flat washers onto each
                        of the four fasteners as shown below.
                                                                        Adapter Flange: 1IMPLR275


                                                                             3/8”-16 x 1” HHCS (4)
                                                                                  3/8” Lock Washer (4)

                                                                                       3/8” Flat Washer (4)

                                                                                           Airis® Mounting Stud:
                                                                                           111382 (4)


















                    12) In the Airis® accessory box locate the Airis® Support Mounting Stud Assemblies (111382). Install
                        a Mounting Stud into each of the four open holes in the Adapter Flange (1IMPLR275) with the
                        threaded stud facing out, as shown above.