Page 19 - H2AIR® Arch
P. 19
®
H2AIR ARCH
Installation
Install Airis® Assemblies onto Air Cannon™ Dryer Housings
7) Some parts have to be removed from the Air Cannon™ assembly in order to properly install the
support mounting studs for the Airis® assembly. Remove the eight fasteners that hold the Air
Cannon™ Inlet Cone (1IMPLR-CO500) onto the Housing Inlet Adapter Flange (1IMPLR275) and
set them aside.
Flat Washers (8)
Inlet Cone
Lock Washers (8)
5/16”-18 x 1” HHCS (8)
8) Remove the Inlet Cone (1IMPLR-CO500) and set aside, shown in the above right image.
9) Use a flat screwdriver to remove the four Nut Retainers (1RETNR650) from the holes that the
Airis® will be mounted to; these four retainers (1RETNR650) will not be reused in the assembly.
Remove the four (4) Nut
Retainers circled; the holes are
to be used to mount the Airis®.
1RETNR650
1MANUL958 Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 15