Page 105 - FreeStyler® Maintenance Manual
P. 105

®
                       MAINTENANCE


                       Chapter 3 General Repairs


                       Spot Free (RO)


                            Membrane Cleaning
                            Clean the membrane with Muriatic Acid (swimming pool acid). Follow the steps below:
                              1)  Turn the system off.
                              2)  Remove the float plug.
                              3)  Remove the product line from the top of the storage tank and put it where the water can go down
                                 the drain.
                              4)  Turn the system back on, the system will be in flush mode for approximately the first two minutes.
                              5)  Wait for the system to come out of flush mode. Then, the system will shut down.
                              6)  Remove the filter housing.
                              7)  Dump out the water without removing the filter.
                              Note:  Make sure the O-ring stays seated.
                              8)  For  systems  with  a  21”  membrane,  pour  a  pint  (16  oz.)  of  Muriatic  acid  into  the  housing  and
                                 replace it on the system. For all other systems a quart (32-oz.) of Muriatic acid.
                              Note:  On multiple membrane systems it may be necessary to repeat the process.

                              Note:  Never use more than a quart per cleaning cycle.
                              9)  Close the reject needle valve(s). See the image below.
                              10)  Open the re-circulation gate valve(s) fully. See the image below.


                                                                                  Flush Solenoid

                                                In from Reject
                                                  Flow Meter
                                                                                             Out to Drain
                                              Out to Membrane
                                                                                             Reject Needle
                                       In from Membrane                                      Valve out to Reject
                                                                                             Flow Meter





                                                                                             Re-circulation Valve




                                                Tap pressure
                                                                                              Out to Pre-Filter
                                                                                              Housing
                                                Pressure Switch


                                                      Inlet Solenoid



                                                                                              In from Carbon
                                                                                              Tank