Page 102 - FreeStyler® Maintenance Manual
P. 102

®
            MAINTENANCE


            Chapter 3 General Repairs


            Manifolds and Wiring

               Each manifold assembly parts breakdown can be found in the replacement part exploded views in
               chapter 8 of the installation manual. Refer to the electrical manual for wiring configuration.


            Spot Free (RO)

            Note:  The  information  in  this  portion  of  the  document  was  supplied  by  Pur-Clean,  A  division  of  New
                   Wave Industries LTD. Pur-Clean equipment is designed for easy installation. However, should you
                   have any questions, please call New Wave Industries LTD. at (916) 978-9990 or (800) 882-8854.

               Carbon Tank


                                   Preprogrammed
                                   Tank Head








                                                                           Carbon







                                                                            1/4” Pea Gravel

                 The main function of the carbon tank is to remove/absorb chlorine. The RO membrane cannot tolerate even small
                 amounts of chlorine.

                 Organic Matter: the carbon tank also removes organic compounds. Excessive organic matter may cause fouling of
                 the membrane.

               Back Flush

                 Free-floating particulate in the water supply can plug the carbon tank and reduce or stop the flow of water.  Back
                 flushing  the  tank  helps  to  prevent  this  and  extends  the  life  of  the  carbon  in  the  tank.  The  tank  head  is
                 preprogrammed to automatically back flush every 7 days.


               Exchanging Carbon
                 The life of the carbon in the tank is 12 to 18 months.  The 1/4” pea gravel and the carbon in the tank should be
                 replaced approximately yearly. After replacing the pea gravel and carbon, run water through the tank to discharge
                 until it is clear for 30 seconds before hooking unit back up.