Page 106 - FreeStyler® Maintenance Manual
P. 106

®
            MAINTENANCE


            Chapter 3 General Repairs


            Spot Free (RO)


               Membrane Cleaning
                 Clean the membrane with Muriatic acid (swimming pool acid). Follow the steps below:
                   11)  Replace the float plug.
                   Note:  If the storage tank is full, it will be necessary to jumper the float plug.

                   12)  Run the system in this mode for 20 minutes.
                   13)  Remove the float plug or jumper.
                   14)  Open the reject needle valve(s) all the way.
                   15)  Close off the re-circulation gate(s) valve.
                   16)  Replace the float plug or jumper.
                   17)  Run the system in this mode for 10 minutes.
                   18)  Open the re-circulation gate valve(s) two full turns.
                   19)  Slowly close the reject valve(s) until the reject flow meter(s) show the correct flow. See the chart
                       below.
                   20)  Open or close the re-circulation gate valve(s) until the pump pressure is correct. See the chart
                       below.
                   21)  The water quality light is probably off. Wait for it to come back on before reattaching the product
                       line to the storage tank.
                   22)  After  two  cleanings,  if  membrane(s)  performance  is  still  unacceptable,  it  may  be  necessary  to
                       replace the membrane(s). See the next page.
               Pressures and Flow Rates Chart

                                                                              MEMBRANE
                               PRODUCTION  PRODUCTION                PUMP                INLET GAUGE
                   MODEL                               REJECT GPM               GAUGE
                                              GPM
                                                                   PRESSURE
                                   GPD
                                                                             PRESSURE PSI   PRESSURE PSI
               PC 3000 STAND      3000         2.1        2.3        180         140         30