Electrical system – electrical components                 EL - 99

                                                                                                                  IN

                                                        e. Remove  the fixing nut for connecting the  high and  low
                                                        pressure tubings with the evaporator.                     DI
                                                        f. Remove the fixing bolts of all tube clamps on the high and
                                                        low  pressure  tubings.  Remove  the  high  and  low  pressure   EG
                                                        tubings.

                                                                                                                  TR

                                                                                                                  AX

              5. Check the A/C high pressure and low pressure tubings if there is any breakage and damage. Replace
              the high pressure and low pressure tubings if necessary.
                                                                                                                  FR
                                                        6. Installing the A/C high and low pressure tubings

                                                        a.  Mount  the  A/C  high  pressure  and  low  pressure  tubings   ST
                                                        into  place. Mount and tighten the  fixing bolts for the tube
                                                        clamps on the A/C high and low pressure tubings.
                                                                                                                  BR
                                                        b. Mount and tighten the fixing nuts for connecting the high

                                                        and low pressure tubings with the evaporator.
                                                                                                                  BW
                                                                                Caution

                                                         Remove the plugs prior to installing the tubing.
                                                                                                                  EL
                                                        c. Mount and tighten the fixing bolts for connecting the high
                                                        and low pressure tubings with the A/C compressor.










                                                        d.  Mount  and  tighten  the  fixing  nut  for  connecting  the

                                                        condenser - evaporator tubing with the condenser.

                                                        e.  Mount  and  tighten  the  fixing  nut  for  connecting  the
                                                        compressor - condenser with the condenser.













                                                          EL-099