Page 1529 - Foton Workshop Manual - Auman EST-M
P. 1529

Electrical system – electrical components                EL - 105

              Check and repair                                                                                    IN

              1. Switch off the ignition switch
              2.  Recover  the  refrigerant  (refer  to  Chapter  EL  electric  system-electric  parts-heating  and   DI
              AC-refrigerant, replacement”)
                                                        3. Removing the compressor                                EG

                                                        a. Removing the fixing bolts from the high and low pressure
                                                        tubes of the compressor.                                  TR


                                                                                                                  AX

                                                                                                                  FR


                                                        b.  Use  a  wrench  to  rotate  the  tension  pulley.  Remove  the
                                                                                                                  ST
                                                        belt


                                                                                                                  BR

                                                                                                                  BW


                                                                                                                  EL

                                                        c.  Disconnect  the  plug  and  socket  connectors  of  the
                                                        compressor.
                                                        d.  Remove  the  compressor  fixing  bolts.  Remove  the
                                                        compressor assembly.






              4. Check the refrigeration oil
              a.  The  gaseous  refrigerant  shall  be  expelled  gradually  from  inside  the  new  replacing  compressor  prior  to
              installation. The drain the refrigeration oil from the new compressor as described below.

              b. Reference values: amount of new compressor refrigeration oil - amount of remained refrigeration oil in the

              used the compressor = amount of refrigeration oil to be drained from the new compressor.

                                                           Caution

              When  checking  amount  of  oil,  refer  to  considerations  on  disassembly  and  installation,  since  some

              refrigeration  oil  may  be  retained  inside  the  A/C  tubings.  If  a  new  compressor  is  installed  without

              draining some refrigeration oil, the amount of oil contained in the system may be too much, that will
              reduce the heat transfer efficiency of the refrigeration loops, and lead to refrigeration failures; if the
              remained amount of oil in the removed compressor is very small, it needs to do the oil leakage check

              and confirm if the correct refrigeration oil had been used.


                                                          EL-105