Page 1557 - Foton Workshop Manual - Auman EST-M
P. 1557
Electrical system – electrical components EL - 133
Failure phenomenon list IN
Use the list below to help you find the reasons of failures. The number presents the order of failure reason
possibilities. Check each part according to this order. Replace the parts if necessary. DI
Failure phenomenon Fault cause Failure elimination
EG
1. leads of ignition switch (no power Check the leads of ignition and supply
Bad ignition supply) power
TR
2. Ignition switch body (broken) Replace the ignition switch body
Ignition switch unable to return 1. Ignition switch body (broken) Replace the ignition switch body
AX
1. Ignition switch body (locking part
Steering wheel not lockable Replace the ignition switch body
damaged)
FR
ST
BR
BW
EL
EL-133