Page 2217 - Foton Workshop Manual - Aumark (BJ1099)
P. 2217

DIAGNOSIS-WIPER AND WASHING SYSTEM                            62-165

                 3.     Check the harness and the connector (the front wiper low-speed relay-BCM control
                        unit)


                 (a).   Ignition switch:"LOCK".


                                                             (b).   Disconnect the front wiper low-speed relay      62
                                                                   R10 and IC16(13) connector.
                                                             (c).   Disconnect the BCM control unit connector
                                                                   C57.
                                                             (d).   Measure the resistance between the No.1
                                                                   pin of R10 and the No.23 pin of C57 with
                                                                   the multimeter on the resistance range.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)
                                                                     Connect the pin by       Specified value
                                                                          multimeter

                                                                        R10(1)-C57(23)             < 2Ω
                 Is the inspection result normal?
                 Yes>To step 4 .
                 No >Repair or replace the harness relating to the connection.


                 4.      Check harness and connector (combination switch-BCM control unit)


                 (a).   Ignition switch:"LOCK".


                                                             (b).   Disconnect the connector C21 of the
                                                                   combination switch (wiper).
                                                             (c).   Disconnect the BCM control unit connector
                                                                   C57.
                                                             (d).   Measure the resistance with the multimeter
                                                                   on the resistance range.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by       Specified value
                                                                          multimeter

                                                                         C21(9)-C57(3)             < 2Ω
                 Is the inspection result normal?
                 Yes>Replace the BCM control unit and carry out Step 5 if the fault remains after replacing.
                 No >Repair or replace the harness relating to the connection.