62-348                           DIAGNOSIS-LIGHTING SYSTEM


                                                      (d).    Use a multimeter to measure the resistance
                                                              between No. C8 terminal of connector C56,
                                                              No. 1 terminal of connector N02. and No.
                                                              1 terminal of connector N05.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                                 C56(C8) - N02(1)            < 2Ω

                                                                 C56(C8) - N05(1)            < 2Ω



                                                      (e).    Use a multimeter to measure the resistance
                                                              between No. 2 terminal of connector N02,
                                                              No. 2 terminal of connector N05 and the
                                                              ground.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                 N02(2) - Grounding          < 2Ω
                                                                 N05(2) - Grounding          < 2Ω



                                                      (f).    Use a multimeter to measure the resistance
                                                              between No. 5 terminal of connector C56
                                                              and rear fog lamp fuse F6.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                    C56(5) - F6              < 2Ω

           Is the inspection result normal?
           Yes>To step 5.
           No >Repair the harness disconnection between connector C16 to C58, C56 to N02, C56 to
                   N05, C56 to F6 and N02, N05 to the ground.