Page 2400 - Foton Workshop Manual - Aumark (BJ1099)
P. 2400
62-348 DIAGNOSIS-LIGHTING SYSTEM
(d). Use a multimeter to measure the resistance
between No. C8 terminal of connector C56,
No. 1 terminal of connector N02. and No.
1 terminal of connector N05.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
C56(C8) - N02(1) < 2Ω
C56(C8) - N05(1) < 2Ω
(e). Use a multimeter to measure the resistance
between No. 2 terminal of connector N02,
No. 2 terminal of connector N05 and the
ground.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
N02(2) - Grounding < 2Ω
N05(2) - Grounding < 2Ω
(f). Use a multimeter to measure the resistance
between No. 5 terminal of connector C56
and rear fog lamp fuse F6.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
C56(5) - F6 < 2Ω
Is the inspection result normal?
Yes>To step 5.
No >Repair the harness disconnection between connector C16 to C58, C56 to N02, C56 to
N05, C56 to F6 and N02, N05 to the ground.
Page 2400