Page 2413 - Foton Workshop Manual - Aumark (BJ1099)
P. 2413
DIAGNOSIS-LIGHTING SYSTEM 62-361
3. Check harness disconnection (LR stop lamp - ground)
(a). Disconnect LR combination lamp connector D52.
(b). Use a multimeter to measure the resistance
between No. 1 terminal of connector D52 62
and the ground.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
D52(1) - Grounding < 2Ω
Is the inspection result normal?
Yes>Find the causes from other symptoms.
No >Repair the harness disconnection between connector D52 and the ground.
Page 2413