Page 2413 - Foton Workshop Manual - Aumark (BJ1099)
P. 2413

DIAGNOSIS-LIGHTING SYSTEM                               62-361

                 3.     Check harness disconnection (LR stop lamp - ground)


                 (a).   Disconnect LR combination lamp connector D52.


                                                            (b).   Use a multimeter to measure the resistance
                                                                   between No. 1 terminal of connector D52          62
                                                                   and the ground.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                       D52(1) - Grounding          < 2Ω

                 Is the inspection result normal?
                 Yes>Find the causes from other symptoms.
                 No >Repair the harness disconnection between connector D52 and the ground.



























































                                                                                                     Page 2413
   2408   2409   2410   2411   2412   2413   2414   2415   2416   2417   2418