DIAGNOSIS-LIGHTING SYSTEM                               62-365

                                                            (d).   Ignition switch:"LOCK".
                                                             (e).   Use a multimeter to measure the resistance
                                                                   between No. 2 terminal of stop lamp
                                                                   switch C09 and the No. 4 terminal of LR
                                                                   combination lamp D52, RR combination
                                                                   lamp D54 and No. 1 terminal of high-             62
                                                                   mounted stop lamp LO1.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                        C09(2) - D52(4)            ≤ 2 Ω

                                                                        C09(2) - D54(4)            ≤ 2 Ω

                                                                        C09(2) - L01(1)            ≤ 2 Ω
                 Is the inspection result normal?
                 Yes>To step 5.
                 No >Repair or replace harness.


                 5.     Check harness short circuit to the grounding


                 (a).   Disconnect connector stop lamp switch C09, left combination lamp D52, right
                 combination D54 and high-mounted stop lamp L01.


                                                            (b).   Use a multimeter to measure the resistance
                                                                   between No. 1 terminal of connector C09
                                                                   and the ground.
                                                                   Standard resistance: (check whether there
                                                                   is a short circuit)


                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                      C09(1) - Grounding         > 1 MΩ


                                                            (c).   Use a multimeter to measure the resistance
                                                                   between No. 4 terminal of connector D52
                                                                   and the ground.
                                                                   Standard resistance: (check whether there
                                                                   is a short circuit)


                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                      D52(4) - Grounding         > 1 MΩ