62-366 DIAGNOSIS-LIGHTING SYSTEM
(d). Use a multimeter to measure the resistance
between No.4 terminal of connector D54
and the ground.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
D54(4) - Grounding > 1 MΩ
(e). Use a multimeter to measure the resistance
between No.1 terminal of connector L01
and the ground.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
L01(1) - Grounding > 1 MΩ
Is the inspection result normal?
Yes>Find the causes from other symptoms.
No >Repair the harness short circuit to the grounding between connector C09 and stop
lamp fuse, D52 and stop lamp, D54 and stop lamp.