04-972                       DIAGNOSTICS - ASSEMBLY INSTRUMENT

                                                      (b)    Disconnect the connector of brake liquid level
                                                             alarm switch A009.
                                                      (c)    Ignition Switch: ON.





      04








           Check whether the brake failure alarm lamp is off

           No > Replace the brake liquid level alarm switch.
           No> go to step 5

                NOTICE

           Brake liquid level alarm switch should not be replaced separately, instead, the oil
           storage cup assembly is required to be replaced.


           5 .    Check the brake liquid level alarm switch signal circuit

                                                      (a)    Use a multimeter to measure the voltage
                                                             between the pin 1 of the brake liquid level
                ON
                                                             alarm switch and ground.
                            A009                             Standard voltage

                          1    2                       Multimeter connection          Standard value

                                                        A009 (1) - grounding          Battery voltage









                                           ftwxd041316


           Check whether the result is normal?
           Yes> go to step 6
           No> go to step 7


           6 .    Check whether the brake liquid level alarm switch circuit is of short circuit