Speed range up to Elevator type Sizes AC Input Voltage
installation & Retrofitting parameter self tuning sequences Battery / UPS Supply I / O Feedback Choke Keypad CAN Page
Introduction
New Protection degree Motor Emergency Input EMI filter
Drives Integrated Lift
[m/s] Geared Gearless [kW] [Vac]
[Hp]
AGL50 AGL50-...-AC4 l 1.0 l IP20 4 - 5.5 - 7.5 kW 380 ... 480, l l / l 6 Digital inputs + 1 Digital output + m m l 40
1 Analog input + 1 Analog output +
3ph
2 Relay outputs
ADL300A-...-4 Optional Expansion cards Optional Expansion cards m l
• EXP-IO-D4-ADL
ADL300A-...-F-4 2 digital inputs - 2 digital outputs + enable input; • EXP-DE-I1R1F2-ADL l m l
Digital encoder 3 Channels card +
l 4 l l IP20 4 ... 75 kW 230-400-480, • EXP-IO-D5R3-F-ADL Repeat + 2 Freeze
3ph
ADL300A-...-4-C 5 digital inputs - 3 relays (NB: The terminals of m l l
this card are not extractable). • EXP-EN/SSI-I1R1F2-ADL
Sinusoidal encoder card - Absolute
ADL300A-...-F-4-C • EXP-IO-D8R4-ADL EnDat + Repeat + 2 Freeze l m l l
8 digital inputs - 4 relays + enable input;
l l l / l • EXP-IO-D8A4R4-ADL • EXP-HIP-I1R1F2-ADL 13
ADL300A-...-2T 8 digital inputs - 2 analog inputs - 2 analog Hiperface encoder 3 Channels card m l
l 1.2 l l IP20 7.5 ... 50 Hp 200-230, 3ph outputs - 4 relays + enable input. + Repeat + 2 Freeze
ADL300A-...-2T-C • EXP-IO-D12A2R4-ADL • EXP-SE-I1R1F2-ADL m l l
Sinusoidal encoder 3 Channels card
8 digital inputs- 4 digital outputs - 2 analog + Repeat + 2 Freeze
inputs - 4 relays + enable input;
ADL300A-...-2M l 1.0 l l IP20 1.1 ... 5.5 kW 230, 1ph • EXP-IO-D16R4-ADL • EXP-SESC-I1R1F2-ADL m l
Sinusoidal SinCos encoder 3
ADL300 ADL300A-...-2M-C 12 digital inputs - 4 digital outputs - 4 relays Channels card + Repeat + 2 Freeze m l l
+ enable input;
ADL300B-...-4
l
m
ADL300B-...-F-4 l m l
l 4 l l IP20 4 ... 75 kW 230-400-480,
3ph
ADL300B-...-4-C m l l
ADL300B-...-F-4-C 8 Digital inputs (NPN/PNP) Digital incremental encoder l m l l
l l l / l + 1 Digital inputs (Enable) 5Vdc TTL 12
ADL300B-...-2T + 4 Relay outputs Absolute Sincos encoder m l
l 1.2 l l IP20 7.5 ... 50 Hp 200-230, 3ph
ADL300B-...-2T-C m l l
ADL300B-...-2M m l
l 1.0 l l IP20 1.1 ... 5.5 kW 230, 1ph
ADL300B-...-2M-C m l l
8 Digital inputs +
AVRy 3 IP20 11 ... 27 400 ... 480, 2 Analog outputs + 2 Analog inputs Sinusoidal / Sincos encoder 50
Regen Drive l l 3ph l l / l + 2 Relay DO l l l m
2 Bipolar analog inputs
AFE200 380 ... 500, + 2 Bipolar analog outputs
Regenerative power - - l l IP20 22kW ... 1.2MW 3ph - - - + 6 Digital inputs m m l l 58
supply units + 2 Digital outputs
+ 2 Relay outputs, single contact