Page 406 - Mechatronics with Experiments
P. 406
JWST499-Cetinkunt
JWST499-c06
392 MECHATRONICS Printer: Yet to Come October 9, 2014 8:1 254mm×178mm
FIGURE 6.64: Thermal flow rate sensor head (transducer, or also called a “probe”) and the
signal conditioning/processing unit (which may be packaged together or separately and
connected by a cable). Reproduced with permission from ABB Ltd.
Fluid
force
Flow
Flow
Fluid force
Vibrating flow tube
Fluid force reacting to
vibration of flow tube
Twist angle
Twist End view of flow tube showing twist
angle