Incident













                                                                                Crevice
                                                                                formation in
                                                                                U/S flange



















             Root Cause

            Carbonic acid corrosion due to presence of CO2/H2O in the gap between flange and gasket.


             Recommendations

            1.  Weld to be buildup and surface finishing to be done in crevice of flange.
            2.  Flange to be kept end blinded to minimize dead zone.

            3.  CS Flange to be replaced with SS.




             Case 13                              Date: 03.12.2019                      Time: 20:10 hrs.



             Incident

            One Bolero Camper of project contractors, accidently rammed into a fire hydrant post on the west side of

            MSQ cooling tower in Street 4A. The vehicle narrowly escaped from skidding off the road towards cooling
            tower and the driver also narrowly escaped from injuries.