Recommendations
1. Additional Support to be provided in Line from 107-E-008B to 107-V-017B to minimize vibration.
2. Stiffener supports to be provided in small bore tapings which was not considered in design.
Case 35 Date: 06.10.2020 Time: 19:00 hrs.
Incident
During charge pump (107-P-003B) normal change over activities, hydrocarbon vapors observed coming
out from common minimum circulation line HPV (3/4”) of charge pump (107-P-003A/B). During checking
weld crack was found in HPV tapping. Pump was stopped immediately, feed-out was done and system
was handed over for leak rectification after proper flushing, purging.
HPV tapping (3/4 inch)
Crack in weld Joint
Main Pipe
Root Cause
Minor vibration in small bore pipe (HPV pipe piece) propagated to weld joint also and led to cracking in
weld joint.
Recommendations
The portion of pipe having this HPV connection to be replaced with straight pipe spool piece of
recommended metallurgy.