ANNEXURE -II
                             PROFORMA FOR SUBMISSION OF R.A.T INSPEaiON REPORTS

              S.No                    Description                                   Remarks
                1    General Particulars of RAT
               1     Name of the Tank                                          Karakambadi Tank
               2     District                                                       Chittoor
               3     Name of the Village and Mandal                         Karakambadi & Renigunta
               4     Latitude & Longitude                                13°39'45.09" and 79°30'33.40"
                                                                   Bridge No.204 @137/14-16 &          Bridge
               5     Affected Railway Bridge and KM                           No.206 @ 138/17-19
               6     Railway section in between stations                      Renigunta to Koduru
                      Distance from Railway Bridge to Bund(along the
                                                                         Railway Line Runs over the Bund
               7     Course of Nallah)
               il    Standard Hydraulic details
               1     Catchment area                                               6.09 Sq.Km
               2     Capacity of the tank                                          34.71 Mcft
               3     Lowest Bed Level                                               106.12
               4     Full Tank Level (FTL)                                          111.08
               5     Maximum Water Level (MWL)                                      112.46
               6     Danger Level (DL)                                              112.76
               7     Top Bund Level                                                 113.07
               8     Top width of the Bund                                    Railway Embankment
               9     Side Slopes                                                U/S 2:1 & D/S 2:1
               10    Area of submergence at FTL                                   128.62 Acres
               11    Area of submergence at MWL
                     Are there ant tanks in the Catchment Area of
                                                                                      Yes
               12    this tank
               13    Are these tanks also classified as RAT's                         Yes
              14     Name and details of these tanks                    Venkatapuram Tank & Yerragunta
               III   Surplusweir
               1     NoofSurplusweir                                                 INo's
               2     Lengthes                                                        6.4 M
               3     Type of Surplusweir                                           B.CWeir
               4     Design Discharge                                             2280 Cusecs
               IV    Sluices
               1     No of Sluices                                                  4 No's
                                                                                    1) 75 M
               2     Location of Sluices                                   2)270 M 3) 635M 4)820M


               3     Maximum Leveldischarge                                      4 X 24 Cusecs
               4     Functional or not
                                                                                  Functional
             V  A    Inspection details
               i)    Date of Inspection                                      )(*.-OX-5-01-0

                                                                              1) Sri.C.WIilson Babu
              ii)    Name & Designation of the inspection officials
                                                                          Assistant Divisional Engineer